T: 0.028
RG6 - Quad Shield - CCS - Plenum - Coax Cable - White - Per FT
RG6 - Quad Shield - CCS - Plenum - Coax Cable - White - Per FT Thumbnail 1 RG6 - Quad Shield - CCS - Plenum - Coax Cable - White - Per FT Thumbnail 2 RG6 - Quad Shield - CCS - Plenum - Coax Cable - White - Per FT Thumbnail 3 RG6 - Quad Shield - CCS - Plenum - Coax Cable - White - Per FT Thumbnail 4

RG6 - Quad Shield - CCS - Plenum - Coax Cable - White - Per FT

Approved for installation in plenum air spaces. CMP Rated, UL Listed

Item # 80-600-435 WH
Sale Price $1.39
1 - 49 50 - 499 500 - 749 750 - 999 1000+
$1.39 $0.82 $0.61 $0.55 $0.49

Plenum RG6 is designed to meet the strictest of electrical codes; our plenum cable meets or exceeds many common cable standards. RG6 is commonly used for digital HDTV, CATV, satellite television, and outdoor TV antennas installations. This cable features a CMP rated Low Smoke PVC jacket. Internally this cable is protected from RFI and EMI interference by a 60% aluminum braid, 100% aluminum foil shield, 40% aluminum braid, and another 100% aluminum foil shield.  Quad shield cable is far superior at rejecting interference and should be used in high EMI/RFI environments. The center conductor is sweep tested to 3.0 GHz and is made from 18 AWG solid Copper-clad Steel. This bulk cable is sold by the foot, order just what you need. RG6 is commonly terminated with an F-Type, BNC, or RCA connector.


  • 75 Ohm
  • 18 AWG Copper-clad Steal Conductor
  • 60% Braid and 40% Braid Shield
  • 2x 100% Foil Shield
  • CMP Rated
  • ETL Listed
  • LS-PVC Jacket
  • Sweep-Tested to 3 GHz.
  • Professional Grade
  • Digital and Analog Applications
  • Foot Markings
  • RoHS Complaint
  • Per foot
  • Max Continuous Length: 1000 FT

Please note: All products that are bought per foot are non-returnable.

Any amount of cable you order above the maximum continuous length of 1000 FT will be sent in separate pieces.

REVIEW SUMMARY for RG6 - Quad Shield - CCS - Plenum - Coax Cable - White - Per FT
No reviews for this product

Q: What does AWG stand for?

A: AWG is the gauge size and denotes the thickness of the cable. The lower the gauge of the cable, the thicker the cable will be. AWG stands for "American Wire Gauge" and is a standardized wire gauge system used throughout the industry.

Q: What does the jacket rating CL2, CM and CMP mean?

  • CL2 is the standard type of PVC jacket used for low voltage cable. CL2 rated cables are often referred to as in-wall rated cables and can be run almost anywhere except plenums. CL2 is more common for non-professional use.
  • CM is standard communications cabling that is not run in walls or in plenum air spaces.
  • CMP is a rating that is given to cables that have passed a stringent burn test and are able to be run through plenum air spaces. Plenum air spaces include drop ceilings and non-ducted HVAC air returns.

Q: What is the difference between 50 and 75 Ohm Cables?

A: 50 and 75 Ohm values refer to the impedance of the coaxial cable. Impedance is a measure of resistance, in the cable, to the flow of electrical energy. There really is no “good” or “bad” impedance, just the right impedance for your application. For 75 Ohm cable, the primary application is the transmission of a video signal. In the case of 50 Ohm cable, it is a data signal that is for the most part being transmitted.

Q: What does “RG” mean?

A: The "RG" is short for "Radio Guide," a term that dates back to the World War II era, when the military made heavy use of coaxial cable, and developed a set of standards to specify different grades of coax and their applications. Even though we still refer to coaxial cables by their original RG numbers today, these standards are now obsolete in regard to actual military use.

Q: What is the difference between RG59, RG6, and RG11?

A: Each of these coaxial cables has a characteristic impedance of 75 ohms. RG59 cable has a smaller diameter center conductor than RG6, resulting in higher signal loss. RG59 cables are typically specified for use as equipment patch cords because of their smaller bend radius and enhanced flexibility. Since RG6 cables exhibit less attenuation than RG59, they are more commonly used for distributed cabling and are recommended for use up to 295 ft. RG11 cables support even less signal loss than RG6 or RG59 because the center conductor diameter is almost twice that of RG59. RG11 cables are recommended for lengths up to 400ft.